Diversified Testing Laboratories has tested and approved Flame-No-More™ for Fabric
in accordance with the following standards:



U.S. Department of Transportation,
Federal Aviation Administration
Compartment Interiors Test

(As Tested by Diversified Labs) see top of page

Reference: Flammability Test Report
Lab Identification No. 3854
Invoice No. 8418

One (1) upholstery fabric sample, identified as Flame-No-More 100% Cotton (8.4 oz./sq. yd.), was received and tested in accordance vith the Department of Transportation, Federal Aviation Administration Regulations for Compartment Interiors, Par. 25.853 (b), Vertical Test. The results are as follows:

Specimen
Indentification
Afterflame
(seconds)
Drippings
(seconds)
Burn Length
(inches)
1 0.0 0.0 4.8
2 0.0 0.0 4.3
3 0.0 0.0 4.6
 
Average 0.0 0.0 4.6

The fabric sample submitted meets the minimum requirements of the above standard. The average burn length may not exceed 8.0 inches and the average afterflame time may not exceed 15.0 seconds.

If there are any questions or when we can be of further assistance, please let us know.

Sincerely,

Karon S. Matkins

Back to the Diversified Testing Labs Reports



National Fire Protection Asssociation
Flame Resistant Textiles Test

(As Tested by Diversified Labs) see top of page

Reference: Flammability Test Report
Lab Identification No. 3854
Invoice No. 8418

One (1) upholstery fabric sample, identified as Flame-No-More, 100% Cotton (8.0 oz./sq. yd.), was received and tested in accordance with the National Fire Protection Association No. 701, "Flame Resistant Textiles and Films, 1989 Edition, (Small Scale Test)". The results are as follows:

Specimen Number After Flame Residual Flame Char Length
  Length Width Length Width Length Width
1 0.0 0.0 0.0 0.0 4.1 4.5
2 0.0 0.0 0.0 0.0 3.9 4.7
3 0.0 0.0 0.0 0.0 4.0 4.4
4 0.0 0.0 0.0 0.0 4.0 4.0
5 0.0 0.0 0.0 0.0 5.3 4.2
 
Average         4.3 4.3

The fabric sample submitted meets the minimum requirements of the above standard. For fabrics whose weight is at least 6.0 oz./sq.yd., but does not exceed 10.0 oz./sq.yd., the average char length may not exceed 4.5 inches with no individual value exceeding 5.5 inches. Additionally, there may be no afterflame which exceeds 2.0 seconds and no residual flame.

If there are any questions or when we can be of further assistance, please let us know.

Sincerely,

Karon S. Matkins

Back to the Diversified Testing Labs Reports



Upholstered Furniture Action Council
Fabric Classification Test

(As Tested by Diversified Labs) see top of page

Reference: Flammability Test Report
Lab Identification No. 3854
Invoice No. 8418

One (1) upholstery fabric sample, identified as Flame-No-More, 100% Cotton (8.4 oz./sq. yd.), was received and tested in accordance with the UPHOLSTERED FURNITURE ACTION COUNCIL Fabric Classification Test Method. The results are as follows:

Test Results
Vertical Char Lengths
20mm 18mm 18mm

Test Results
Class I

If there are any questions or when we can be of further assistance, please let us know.

Sincerely,

Karon S. Matkins

Back to the Diversified Testing Labs Reports



British Standards Institution
Fire Test for Furniture

(As Tested by Diversified Labs) see top of page

Reference: Flammability Test Report
Lab Identification No. 3854
Invoice No. 8418

One (1) upholstery fabric sample, identified as Flame-No-More, 58% Rayon/20% Cotton/22% Polyester (9.8 oz./sq. yd.), was received and tested in accordance with BRITISH STANDARDS INSTITUTION "Fire Test for Furniture, 5852. Part 1. Methods of Test for the Ignitability by Smokers' Materials of Upholstered Composites for Seating." Per Section 10. (a), "The following test results relate only to the ignitability of the combination of materials under the particular conditions of test; they are not intended as a means of assessing the full potential fire hazard of the materials in use."

The sample submitted was tested to Section 9.3 Butane Flame Test. The results are as follows:

Ignition Source Test Results
Butane Flame Source 1 #1 - No progressive smouldering or flaming
Butane Flame Source 1 #2 - No progressive smouldering or flaming

The sample submitted therefore meets minimum requirements of the above standard when tested to butane flame ignition source 1.

If there are any questions or when we can be of further assistance, please let us know.

Sincerely,

Karon S. Matkins

Back to the Diversified Testing Labs Reports


Note:  The above reports have not been changed, they are posted as written. Notice the Address change in the contact info.

 

Hit Counter

 

Corp..
P.O. Box 107
Grover, NC 28073

Please call or write for information.
Go to the index to contact distributors. If there isn't one near you, call us.

Voice: (704) 937-7795  
Fax: (704) 937-7795

EMail: info@flametardNoSPAM.com
please remove the NOSPAM from above before sending, thanx
            IMPORTANT!! Please put your phone number in any emails. Some Spam Blockers can keep you from receiving our emails.

 

Copyright 2002,2003,2004,2005,2006,2007,2008© Corp.

Flame-No-MoreTM and Flame-OutTM are registered trademarks of the CareChem Corporation (now Southern Polymer, Inc.).

Hosted by Maintained by www.hilton2000.com. Contact the webmaster with site related questions.

Modified last 07/23/2008 07:36 PM -0500 jh