REPORT OF TEST
June 26, 1990 - Test Number 035012
| CLIENT: |
CareChem Corporation
First Plaza
1985 Tate Blvd. SE
Suite 737 Box 37
Hickory, NC 28602 |
| SUBJECT: |
One wood panel submitted and identified by the client as: Coated (new product) wood
panel |
AUTHORIZATION:
Client's letter of May 3, 1990.
PURPOSE:
To determine flame retardancy of the coating during accelerated weathering.
PROCEDURE:
Accelerated weathering was accomplished by exposing the panel in a QUV Accelerated
Weathering Tester maintained in accord with ASTM G-53. The Tester was programmed to
alternate 4 hour periods of ultraviolet B at 60°C with 4 hour periods of water
condensation at 50°C. After 500. 750 and 1000 hours of accelerated weathering the panel
was tested for flame retardancy by holding a flame beneath the panel for 5 seconds and
observing what happened.
RESULTS:
After 500 hours of accelerated weathering flame impingement caused the panel to flame for
a few seconds. On the back where white deposit was still visible the flame went out at the
deposit. On the front where the deposit was no longer visible the flame charred the
surface for a few inches and the extinguished itself.
After 750 hours the panel sustained a flame for 44l minutes mainly on the exposed side.
No intumescence occurred on the exposed side but did on the backside.
After 1000 hours the panel sustained a flame for a second or two on one edge but could
not really be ignited. Flame was impinged upon the panel in many different spots without
igniting.
SIGNED FOR THE COMPANY
By: William S. Gilman
Note: The above report has not been changed,
it is posted as written.